This paper mainly discusses the implementation of the system based on DSP for distribution network parameters acquisition and processing, and also introduces the relevant background knowledge.. Through learning the knowledge of DSP, FFT algorithm and parameters of distribution network calculation method, from the system design requirements of completed the hardware circuit design and implementation as well as the realization of software programming. Through the debugging of hardware and software, the whole design is finished from the analysis and design to the whole process.. During the graduation design research phase of a few months, I have completed the comparison and demonstration of the relevant information and the comparison and demonstration of various solutions.,The hardware circuit and the software program design and function test work, achieved the design request of this graduation design. Summary the graduation design, mainly in the following four aspects:
(1) on the analysis of the parameters of the distribution network based on, through harmonic analysis method to calculate the parameters of the distribution network. After that, the harmonic analysis method and the calculation method of the FFT algorithm are realized, which provide a powerful theoretical support for the calculation of the distribution network parameters..
(2) the hardware platform system based on TI is built, and the advantage of the data processing is fully played.,DSP not only completed the data acquisition function, and the calculation of the harmonic analysis and the parameters of the distribution network, the real-time monitoring of the requirements. This hardware structure can not only meet the requirements of high accuracy, but also a low-cost hardware configuration scheme.
(3) design and complete the entire DSP software module code written, the system analysis of the DSP data sampling, processing and other unit control. DSP through the timer control to achieve the A/D sampling control, and through the preparation of FFT algorithm program, data processing procedures, the calculation of the distribution network parameters.
(4) the software design and hardware design scheme, completed the design of a distribution network data acquisition and processing system, through the simulation and debugging of hardware module and software module, to verify the correctness of the system to solve the problem. At the same time, in the laboratory, the whole power is debugged, the experimental results show that the design can complete the basic monitoring requirements of the distribution network parameters.. Due to the limited time, some problems in the process of design and production of the system have been found to be further improved, and the main problems are as follows:
(1) due to the design mainly focus on the acquisition and the processing of the parameters of the distribution network, the parameter display function does not concern, so this design cannot be the display of the parameters of the distribution network on the screen, but only through access to a data memory address to read the parameter values, which to a considerable extent, limits the real-time monitoring of the parameters of the distribution network, based on this design in a data display program, in order to make the parameters of the distribution network real-time monitoring effect is better.
(2) this design has no external data memory, so it can't store the parameters of the distribution network.. The design of the parameters of the data is stored in the loop,The maximum saved data is five, and then the circulation is saved.. To save more historical data for researchers to access and study, the external data memory is available, and the parameter data is saved to an external memory for five.
(3) due to the DSP only a sampling holder, each only acquisition data, not simultaneous acquisition of multi-channel data and can only be collected, which will affect the precision of the data acquisition in a certain extent. In order to achieve real-time acquisition of multi-channel data, an external A/D sampling chip can be used to collect multi-channel data, and then read into DSP for processing.
(4) the system using the timer interrupt, default, the distribution network voltage and frequency is 50Hz to calculate the timing interval, but in fact voltage frequency is not immutable, which will also affect the accuracy of the final data. In order to solve this problem, a frequency measurement unit can be set up to monitor the frequency, and then change the timer period to get more accurate data.. If from the above aspects of the system to improve the function of the system will be more perfect, intelligent will greatly improve, more conducive to real life use.
正在翻譯中..